CCWFQ - MT TONER (P-P), RP605Z

  • MSDS: CCWFQ
  • Manufacturer: MINOLTA CORP
  • Product Name: MT TONER (P-P), RP605Z
  • National Stock Number: 6850-00N028646
Product Identification

Product ID:MT TONER (P-P), RP605Z
MSDS Date:04/02/1993
FSC:6850
NIIN:00N028646
MSDS Number: CCWFQ

Responsible Party
MINOLTA CORP
101 WILLIAMS DRIVE
RAMSEY, NJ 07446
US

Emergency Phone: 201-825-4000

Info Phone: 201-825-4000

Cage: GO339

Contractor
MINOLTA CORPORATION
RAMSEY, NJ 07446 US

Telephone: 201-825-4000

Cage: 23736

Ingredients

STYRENE ACRYLATE COPOLYMER

CAS: 25153-46-2

Fraction By Weight: >80%

OSHA PEL N/K

ACGIH TLV: N/K


CARBON BLACK

CAS: 1333-86-4

RTECS: FF5800000

Fraction By Weight: 5-10%

OSHA PEL 3.5 MG/M3

ACGIH TLV: 3.5 MG/M3


ORGANIC PIGMENT

CAS: 32517-36-5

Fraction By Weight: 1-5%

OSHA PEL N/K

ACGIH TLV: N/K


PROPENE POLYMERS; (POLYPROPYLENE)

CAS: 9003-07-4

RTECS: UD1842000

Fraction By Weight: 1-5%

OSHA PEL N/K

ACGIH TLV: N/K


SILICA GEL; (AMORPHOUS SILICA)

CAS: 112945-52-5

RTECS: VV7310000

Fraction By Weight: <1%

OSHA PEL 6 MG/M3

ACGIH TLV: 10 MG/M3

Hazards

LD50 LC50 Mixture:LD50:(ORAL,RAT) >5 G/KG.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:MINIMAL RESPIRATORY TRACT
IRRITATION MAY OCCUR AS WITH EXPOSURE TO LARGE AMOUNTS OF ANY
NONTOXIC DUST. MAY CAUSE COUGH AND RAISE PHLEGM. TOXICOLOGY:TONER
PRESENTS LOW HAZ FOR USUAL OCCUP SETTING S. BASED ON AVAIL DATA,
HUMAN EXPOS TO TONER HAS BEEN SHOWN TO CAUSE MIN RESP TRACT IRRIT
AS MAY OCCUR (EFTS OF OVEREXP)
Explanation of Carcinogenicity:CARBON BLACK:IARC MONOGRAPHS ON
EVALUATION OF CARCINOGENIC RISK OF CHEMICALS TO MAN, VOL 65, PG
24-27, 1995:GROUP 2B.
Effects of Overexposure:HLTH HAZ:W/LG AMTS OF ANY NON-TOX DUSTS. RSLTS
OF ONE ANIMAL STUDY WHERE RATS INHALED TONER THAT WAS TEN TIMES
MORE RESPIRABLE THAN COMMERCIALLY AVAIL TONER WERE OBSERVED TO HAVE
NO LUNG CHANGES AT LO W EXPOS (MOST RELEVANT LEVEL TO POTNTL HUMAN
EXPOS). AT HIGHER LEVELS A SLIGHT DEGREE OF LUNG FIBROSIS WAS (SUPP
DATA)
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHALATION:WASH NOSTRILS, RINSE MOUTH. INGESTION:DILUTE
STOMACH CONTENTS WITH SEVERAL GLASSES OF WATER. EYES:FLUSH WITH
WATER FOR AT LEAST 15 MINUTES. SKIN:WASH WITH SOAP & WATER.

Fire Fighting

Extinguishing Media:WATER, FOAM, DRY CHEMICAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . AVOID INHALATION OF SMOKE.
Unusual Fire/Explosion Hazard:IF DISPERSED IN AIR, TONER, LIKE MOST
FINELY DIVIDED ORGANIC POWDERS, MAY FORM AN EXPLOSIVE MIXTURE.

Accidental Release

Spill Release Procedures:IF SPILLED, SWEEP UP OR VACUUM.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NONE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . NONE REQUIRED WHEN USED AS INTENDED IN
MINOLTA EQUIPMENT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:EYE WASH FOUNTAIN & DELUGE SHOWER WHICH MEET
ANSI DESIGN CRITERIA .
Work Hygienic Practices:NONE.
Supplemental Safety and Health
EFTS OF OVEREXP:OBSERVED DUE TO EXCESSIVE AMOUNTS OF DUST RETAINED IN
LUNGS FOR A PROLONGED INTERVAL. INHAL:LC50:(RATS) >0.41 MG/L FOR 4
HRS (THIS WAS HIGHEST ATTAINABLE CONC. THERE WERE NO DEATHS DUR ING
STUDY). EYE (RABBIT):IRRITANT. TONER, AS A MIXTURE, IS CONSIDERED A
NUISANCE DUST.

Chemical Properties

Spec Gravity:1.15 (H*2O=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:BLACK POWDER; FAINT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:PRODUCTS OF COMBUSTION ARE TOXIC.
AVOID BREATHING OF SMOKE.

Disposal

Waste Disposal Methods:WASTE MAY BE DISPOSED OR INCINERATED UNDER
CONDITIONS WHICH MEET ALL FEDERAL, STATE & LOCAL ENVIRONMENTAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.